Kyoritsu

KEW 1021R Digital Multimeter

RM 170.00

RM 200.00 -15%

• Elegant and easy-to-use cabinet
• Large display with 6000 counts and Backlight
• Enhanced current measuring function using an external clamp sensor
• Two detachable holders, flat and wing type
• Accurate reading with True RMS
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V



Product Variation


Product Description

>

DC V 6.000/60.00/600.0V (auto range)
±0.5%rdg ±3dgt
DC mV 600.0mV
±1.5%rdg ±3dgt
DC Clamp Sensor 60.00/200.0A (auto range)
±1.5%rdg ±3dgt + Sensor accuracy
AC V 6.000/60.00/600.0V (auto range)
±1.0%rdg ±3dgt [40 - 500Hz]
AC mV 600.0mV
±2.0%rdg ±3dgt [40 - 500Hz]
AC Clamp Sensor 60.00/200.0A (auto range)
±2.0%rdg ±3dgt + Sensor accuracy [40 - 500Hz]
DC A 6.000/10.00A (auto range)
±1.5%rdg ±3dgt
AC A 6.000/10.00A (auto range)
±1.5%rdg ±3dgt[45 - 500Hz]
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range)
±0.5%rdg ±4dgt (600Ω),
±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ)
±1.5%rdg ±3dgt (40MΩ)
Continuity buzzer 600Ω (Buzzer sounds below 90Ω)
Diode test Open-loop voltage: < 3.0V
Capacitance 60.00/600.0nF/6.000/60.00/600.0/1000µF
±2.0%rdg ±5dgt (60/600nF)
±5.0%rdg ±5dgt (6/60/600/1000µF)
Frequency ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt
ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt
DUTY 10.0 - 90.0% ±1.0%rdg ±3dgt [50/60Hz]
Applicable standards IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V
IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS)
Power source R03 (1.5V) × 2
Dimensions 155(L) × 75(W) × 40(D)mm
Weight 250g Approx. (including batteries)
Included Accessories Wing-type holder, Flat-type holder, 7066A (Test leads),
8919 (Ceramic fuse [10A/600V]) × 1 (included),
9097 (Carrying case), R03 × 2, Instruction manual
Optional Accessories 7234 (Alligator clip), 8161 (AC clamp adaptor)
8115 (AC/DC clamp sensor), 9189 (Magnet hanger strap)